Rigicon Penile Prosthesis: Features, Advantages and Disadvantages

Reading Time: 6 min
Last Updated:
Op. Dr. Yaşar Başağa
Published Date:
Op. Dr. Yaşar Başağa
RIGICON PENILE PROSTHESIS
Table of Contents

When choosing a penile prosthesis, the same brand and model will not suit every patient. Anatomy, expectations and budgets differ. The advantages and disadvantages of each prosthesis should therefore be understood, and all available options should be presented to the patient. Personal preferences should also be considered.

Rigicon entered use later than the other penile prosthesis brands. Its products have undergone improvements during this period. However, because it is relatively newer, 15–20-year outcomes are not yet available.

Main Components of the Rigicon Inflatable Penile Prosthesis

Inflatable penile prostheses are designed to provide reliable rigidity. The system consists of three main components:

  • A reservoir that stores fluid
  • Cylinders placed inside the penis
  • A pump that controls inflation and deflation

Rigicon’s Infla10 X and AX models differ in how their cylinders expand.

Reservoir Features

The reservoir stores the fluid needed to operate the prosthesis. It can be placed within the abdomen or behind the abdominal muscle.

Rigicon offers reservoirs in different sizes and shapes. The adaptive reservoir is designed to supply fluid to the cylinders while remaining flexible enough to reduce external visibility.

Ectopic Reservoir Placement

Placing the reservoir behind the abdominal muscle is called ectopic reservoir placement.

One advantage of this position is that the reservoir can be removed more easily if revision surgery becomes necessary. The space of Retzius, beside the bladder, contains large iliac blood vessels. Removing reservoirs from this area can be difficult, so the existing reservoir may be left in place during revision surgery.

If the patient is not very thin and the reservoir is not externally visible, an adaptive reservoir can be used in this position. The abdominal muscle is stronger than the peritoneal membrane behind the reservoir and pushes it inwards, helping prevent it from becoming visible.

Lockout Valve to Prevent Unintended Inflation

The reservoir contains a locking mechanism called a lockout valve.

Pressure within the reservoir can cause fluid to move into the cylinders unintentionally. This may partially inflate the prosthesis without the patient operating the pump. This is known as autoinflation and can occur during everyday activities.

The purpose of the lockout valve is to prevent this unintended inflation.

Differences Between Infla10 X and AX

Infla10 X cylinders expand in girth, while Infla10 AX cylinders expand in both girth and length.

Both models can reach a cylinder diameter of up to 23 millimetres. However, using wider cylinders does not necessarily mean that the penis will become wider.

Penile length and girth depend on the flexibility of the tunica albuginea, the tissue surrounding the penis. The prosthesis expands to the dimensions permitted by the penile tissue.

Do Wider Cylinders Enlarge the Penis?

Penile prostheses are intended to provide a full erection, rather than enlarge the penis.

Wider cylinders can contribute to resistance against pressure applied along the penis, known as axial rigidity. However, the achievable length and girth depend on the existing penile structure and tissue flexibility.

Cylinder Rear Tips and Connecting Tubing

The notch at the rear end of the cylinders and the angle at which the connecting tubing exits help make surgical placement easier.

The tubing exit angle also helps reduce wear over time. Since a significant proportion of mechanical problems can originate from the tubing, the durability of these components is important.

An excessively long structure at the base of the cylinder can also negatively affect axial rigidity.

Four-Layer Cylinder Structure

Rigicon cylinders have four layers:

  1. An inner silicone layer
  2. A textile layer
  3. A second silicone layer
  4. A slippery outer silicone layer

The textile layer provides expansion and flexibility while contributing to cylinder durability.

The purpose of the slippery outer silicone layer is to reduce friction between the cylinders and connecting tubing.

The cylinders move during inflation. As they move, the tubing and cylinders may come into contact. Over time, friction can cause wear, deformation and mechanical problems.

During surgery, contact between the connecting tubes is reduced as much as possible. The slippery outer layer also aims to reduce friction and help the prosthesis function for longer.

Cylinder Lengths and Rear Tip Extenders

Rigicon offers cylinder lengths of 12, 15, 18, 20, 22 and 24 centimetres.

The availability of lengths in two-centimetre increments after 18 centimetres provides an advantage for surgeons who prefer not to use rear tip extenders.

Rear tip extenders are available in sizes up to 6 centimetres. Cylinder and extender selection depends on the internal and external penile lengths, as well as the surgeon’s preference.

Thinner NarrowBody cylinder options are also available for challenging cases.

What Is a Hydrophilic Coating?

A hydrophilic coating allows the outer surface of the prosthesis to retain water.

When the prosthesis is immersed in an antibiotic solution, the surface can retain that solution. This is one of the features that provides an advantage regarding infection.

PALS Pump Features

When inflating and deflating the prosthesis, the patient operates the pump rather than interacting directly with the cylinders or reservoir. Pump usability is therefore important.

The PALS pump has a soft and efficient squeezing mechanism. Squeezing the pump transfers the applied force to the cylinders, allowing them to fill and empty.

Inflation and Deflation Valves

The inflation and deflation valves are located within the same mechanism. This simpler structure is one of the features intended to help reduce pump-related mechanical problems.

The deflation button is positioned on the side and has a raised profile. Its prominence makes it easier to use.

Lifetime Warranty and Revision Costs

A lifetime product warranty is one of the features that may influence the choice of a Rigicon prosthesis. It may be particularly important for younger patients when considering possible future revisions.

The product warranty and hospital or surgeon fees are separate matters. Hospital and surgeon expenses may still need to be paid if revision surgery becomes necessary.

Limitations of Long-Term Outcomes

Rigicon is relatively newer than the other prosthesis manufacturers. Consequently, 15–20-year outcomes are not yet available.

This can be considered a disadvantage. Product development nevertheless continues.

Features That Facilitate Surgical Placement

The tubing exit angle, slippery surface and ease of placement are important surgical features.

A smoother and more comfortable operation also matters for the patient. Easier surgical placement can contribute to reducing infection and bleeding risks.

Single-Use Surgical Instruments

Rigicon provides single-use dilators, measuring instruments and needle-passing instruments for use during surgery.

Reusable instruments that can be sterilised are also commonly used. Opening single-use instruments for the first time for the patient provides advantages in infection-related safety and ease of surgical use.

Frequently Asked Questions (FAQ)

Infla10 X expands in girth. Infla10 AX expands in both girth and length.

Wider cylinders do not necessarily make the penis wider. The flexibility of the tunica albuginea determines the dimensions the tissue can accommodate.

No. Its purpose is to provide the rigidity required for a full erection.

It is the placement of the reservoir behind the abdominal muscle. Removing the reservoir can be easier from this position if revision surgery is required.

It helps prevent unintended fluid movement from the reservoir into the cylinders and stops the prosthesis from inflating on its own.

It helps reduce friction between the cylinders and connecting tubing, with the aim of reducing wear and mechanical problems.

It is a coating that allows the outer surface of the prosthesis to retain water and antibiotic solution.

It has a soft squeezing mechanism. The inflation and deflation valves are located within the same mechanism, and the prominent deflation button on the side makes it easier to use.

The product warranty and hospital or surgeon fees are separate. These expenses may still need to be paid during revision surgery.

No. Because Rigicon is relatively newer than the other brands, 15–20-year outcomes are not yet available.

No. Anatomy, expectations, budget and preferences differ, so the brand and model are selected individually.